C-COM Satellite iNetVu Guida alla Risoluzione dei Problemi Pagina 25

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 88
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 24
iNetVu Troubleshooting Guide
C-COM Satellite Systems Inc.
2. If the Mobile Platform physically moves but the angle doesn’t change
Possible Causes:
Inclinometer (Tilt Sensor)
Sensor Cable
Internal Wiring Harness
7000 Controller
a. Test the Controller Sensor Pins for voltage. On the controller sensor connector test pins 9 and
18 for 12VDC. If you are getting power proceed to testing the Sensor Cable and Internal Wiring
Harness. If you are not getting power please contact C-COM Technical Support.
Insert positive lead while grounding the negative lead
b. Use the Inclinometer Sensor Circuit Diagram on the following page to confirm continuity of the
cabling. Set the voltmeter to beeper or continuity mode. If the Sensor Cable and Internal Wiring
Harness pass continuity, this will conclude the issue is the Tilt Sensor (Inclinometer).
Sensor Cable Wiring Harness